
|

|

|
Semi-Micro GPC/SEC Columns
Save 60% Eluent

SDV Columns
GPC/SEC Polymers in Unpolar and
Medium Polar Organic Solvents
| Field of |
Application |
| Eluents |
THF, Toluene, TCM, DCM |
| Applicability |
Poly(styrene), Poly(vinyl chloride),
Poly(carbonate), Elastomers, Resins
and others |
| Specifications |
|
| Incompatibility |
Water, drying, and freezing |
| Material |
Styrene-divinylbenzene copolymer
network |
Maximum
Pressure |
45 - 150 bar (650 - 2180 psi),
depending on porosity |
Maximum
Temperature |
100 °C |
| Particle Size |
3 µm |
| Recommended |
Column Combination |
Medium
Molecular
Weight (MW) |
1 000 Å + 100 000 Å + 1 000 000 Å |
Low Molecular
Weight (MW) |
100 Å + 1 000 Å + 10 000 Å |
| Porosity |
Molar Mass
Range [Da] |
Partnumber |
| linear M |
100 - 1 000 000 |
sdm052503lim |
| precolumn |
|
sdm050303 |
| 50 Å |
100 - 5 000 |
sdm0525035E1 |
| 100 Å |
100 -10 000 |
sdm0525031E2 |
| 500 Å |
100 - 30 000 |
sdm0525035E2 |
| 1 000 Å |
100 - 60 000 |
sdm0525031E3 |
| 10 000 Å |
500 - 700 000 |
sdm0525031E4 |
| 100 000 Å |
1 000 - 1 000 000 |
sdm0525031E5 |
| 1 000 000 Å |
1 000 - 3 000 000 |
sdm0525031E6 |
| linear S |
100 - 150 000 |
sdm052503lis |
PFG Columns
Christalline Polymers/Fluorinated Organic Solvents
| Field of |
Application |
| Eluents |
HFIP, TFE, other fluorinated |
| Applicability |
Crystalline polymers, Poly-esters,
Nylons, Poly(lactide), POM, etc. |
| Specifications |
|
| Incompatibility |
Freezing |
| Material |
Modified silica |
Maximum
Pressure |
150 - 200 bar (2180-2900 psi),
depending on porosity |
Maximum
Temperature |
90 °C |
| Particle Size |
5 µm |
| Recommended |
Column Combination |
Medium
Molecular
Weight (MW) |
1 000 Å + 1 000 Å |
Low Molecular
Weight (MW) |
100 Å+ 100 Å |
| Porosity |
Molar Mass
Range [Da] |
Partnumber |
| linear M |
100 - 1 000 000 |
pfm052505lim |
| precolumn |
|
pfm050305 |
| 100 Å |
100 - 100 000 |
pfm0525051E2 |
| 300 Å |
1 000 - 300 000 |
pfm0525053E2 |
| 1 000 Å |
10 000 - 1 000 000 |
pfm0525051E3 |
| linear S |
100 - 300 000 |
pfm052505lis |
SUPREMA Columns
Aqueous GPC/SEC, Neutral/Anionic Polymers
| Field of |
Application |
| Eluents |
Water (with salts/buffers, MeOH,
ACN) pH: 1.5 – 13 |
| Applicability |
Neutral and anionic polymers,
(PEO, PEG, Pullulan, Dextran,
Hyaluronic acid, etc.) |
| Specifications |
|
| Incompatibility |
Drying and freezing |
| Material |
Polyhydroxy methacrylate
copolymer network |
Maximum
Pressure |
50 - 80 bar (725 -1160 psi),
depending on porosity |
Maximum
Temperature |
80 °C |
| Particle Size |
5 µm |
| Recommended |
Column Combination |
Medium
Molecular
Weight (MW) |
30 Å + 1 000 Å + 1 000 Å |
Low Molecular
Weight (MW) |
100 Å + 100 Å |
| Porosity |
Molar Mass
Range [Da] |
Partnumber |
| linear M |
1000 - 1 000 000 |
sum052505lim |
| precolumn |
|
sum050305 |
| 30 Å |
100 - 30 000 |
sum0525053E1 |
| 100 Å |
100 - 100 000 |
sum0525051E2 |
| 300 Å |
100 - 300 000 |
sum0525053E2 |
| 1 000 Å |
100 - 1 000 000 |
sum0525051E3 |
| linear S |
100 - 100 000 |
sum052505lis |
PROTEEMA Columns
Aqueous GPC/SEC, Proteins
| Field of |
Application |
| Eluents |
Water, water with salt/buffer pH < 7 |
| Applicability |
Neutral and synthetic proteins,
Peptides, Enzymes, Collagens |
| Specifications |
|
| Incompatibility |
Drying and freezing |
| Material |
Special modified silica |
Maximum
Pressure |
150 - 200 bar (2180 - 2900 psi),
depending on porosity |
Maximum
Temperature |
70 °C |
| Particle Size |
3 µm |
| Porosity |
Molar Mass
Range [Da]* |
Partnumber |
| 300 Å |
1 000 - 1 200 000 |
prm0525033E2 |
| precolumn |
|
prm050303 |
| 100 Å |
100 - 150 000 |
prm0525031E2 |
*based on protein molecular weight, for other water soluble macromolecules
(e.g. pullulane) separation range ends at 50 000 and 400 000 Da.
| Order |
Information |
| GRAM, POLEFIN, NOVEMA, MCX columns |
on request, other porosities on request |
| Column dimensions |
4.6 mm I.D. x 250 mm length (30 mm precolumn), other dimensions on request |
For a .pdf copy of this data click here.
|
|
|
|